The smallest unit in the lineup: a complete unit with compressor, tank and pump in a compact stainless steel housing, built for low coolant temperatures from −10 to +15 °C. Connect it to your loop and plug it in.
| Model | Cooling capacity | BTU/h | Tons | Power supply | Tank | Water temp range | Dimensions (L×W×H) |
|---|---|---|---|---|---|---|---|
| Chilly 45 (M-LT) | 4.2 kW* | 14,300 | 1.2 | 230 V or 208 V · 1 ph | 25 L (6.6 gal) | −10 to +15 °C | 765 × 770 × 515 mm · 81 kg |
Four models from 6.4 to 12.7 kW on a compact, mobile chassis, including the inverter-driven 70i for loads that rise and fall. The fan sits on top, so the unit can stand against a wall on any side.
| Model | Cooling capacity | BTU/h | Tons | Power supply | Tank | Water temp range | Dimensions (L×W×H) |
|---|---|---|---|---|---|---|---|
| Chilly Max 50 | 6.4 kW* | 21,800 | 1.8 | 230 V · 1 ph or 3 ph | 30 L (7.9 gal) | −10 to +40 °C | 853 × 715 × 1014 mm · 145 kg† |
| Chilly Max 70iInverter | 8.0 kW* | 27,300 | 2.3 | 208 V · 1 ph · 60 Hz | 30 L (7.9 gal) | −10 to +40 °C | 720 × 940 × 1022 mm · weight per configuration |
| Chilly Max 90 | 10.7 kW* | 36,500 | 3.0 | 230 V · 1 or 3 ph; 208 V · 1 ph | 30 L (7.9 gal) | −10 to +40 °C | 853 × 715 × 1014 mm · 145 kg† |
| Chilly Max 110 | 12.7 kW* | 43,300 | 3.6 | 230 V · 1 ph or 3 ph | 30 L (7.9 gal) | −10 to +40 °C | 853 × 715 × 1014 mm · 145 kg† |
Fixed-speed and inverter (i) models from 13 to 79 kW, in several voltage versions. The cooling circuit sits above a large insulated stainless tank, warm air discharges straight up, and side panels lift off for service. Larger units and dual-circuit versions are built to order. Meets the EU Ecodesign Directive on energy efficiency.
| Model | Cooling capacity | BTU/h | Tons | Power supply | Tank | Water temp range | Dimensions (L×W×H) |
|---|---|---|---|---|---|---|---|
| MCK 140iInverter | 13.0 kW*** | 44,400 | 3.7 | 208 V · 1 ph · 60 Hz | 120 L (32 gal) | −10 to +40 °C | 715 × 715 × 1603 mm · weight per configuration |
| MCK 141 | 15.0 kW* | 51,200 | 4.3 | 380–415 V or 440–480 V · 3 ph | 120 L (32 gal) | −10 to +40 °C | 715 × 715 × 1575 mm · 210 kg |
| MCK 181 | 19.2 kW* | 65,500 | 5.5 | 380–415 V or 440–480 V · 3 ph | 300 L (79 gal) | −10 to +40 °C | 1000 × 1000 × 2055 mm · 310 kg |
| MCK 181iInverter | 21.0 kW*** | 71,700 | 6.0 | 440–480 V · 3 ph · 60 Hz | 300 L (79 gal) | −10 to +40 °C | 1000 × 1000 × 2055 mm · weight per configuration |
| MCK 221 | 25.9 kW* | 88,400 | 7.4 | 380–415 V or 440–480 V · 3 ph | 300 L (79 gal) | −10 to +40 °C | 1000 × 1000 × 2055 mm · 330 kg |
| MCK 271 | 29.4 kW* | 100,300 | 8.4 | 380–415 V or 440–480 V · 3 ph | 300 L (79 gal) | −10 to +40 °C | 1000 × 1000 × 2055 mm · 340 kg |
| MCK 321 | 38.6 kW* | 131,700 | 11.0 | 380–415 V or 440–480 V · 3 ph | 300 L (79 gal) | −10 to +40 °C | 1000 × 1000 × 2055 mm · 350 kg |
| MCK 320iInverter | 38.0 kW*** | 129,700 | 10.8 | 440–480 V · 3 ph · 60 Hz | 300 L (79 gal) | −10 to +40 °C | 1500 × 1000 × 2055 mm · weight per configuration |
| MCK 641 | 79 kW** | 269,500 | 22.5 | 380–415 V or 440–480 V · 3 ph | 300 L (79 gal) | −10 to +40 °C | 1000 × 1000 × 2055 mm · 380 kg |
| Chilly 45 | Chilly Max | MCK Series | |
|---|---|---|---|
| Capacity | ~4.2 kW | 6.4 – 12.7 kW | 13 – 79 kW |
| Models | 1 | 4 (50 · 70i · 90 · 110) | 9 listed; more built to order |
| Inverter (i) models | – | 70i | 140i · 181i · 320i; other models on request |
| Tank | 25 L stainless | 30 L stainless | 120 – 300 L stainless |
| Mobility | Compact, portable | Casters standard | Wheels on 141; optional above |
| Heat rejection | Front fan | Top discharge | Top discharge |
| Installation | Indoor | Indoor | Indoor |
| Best for | Benches, single servers | Small clusters, edge | Multi-rack rooms |
We share data sheets and installation manuals once we have sized the right unit with you. That way you get documents for the exact model, voltage and configuration you will install, not a catalog to guess from.
Start with your numbers →The standard range covers most compute loads, but Quantor's engineers can customise a unit around your application and demand. Tell us what you are cooling and we will work out the configuration with you.
Chilly Max and MCK sizes come as fixed-speed units, and selected sizes also come as i models with an inverter compressor. If your equipment runs at full load most of the time, the fixed-speed unit is the simpler choice. If the load rises and falls through the day, the i model follows it. Other sizes can be built as i models; a data sheet and quote take about two weeks.
Compressor speed follows the heat load, holding supply temperature steady with fewer on/off cycles and lower energy use at part load.
Available on request for Chilly Max and MCK. It holds constant pressure as flow changes, from one cold plate to eight, up to 7 bar (100 psi).
Condenser fan speed adjusts to conditions for quieter, more efficient heat rejection.
Modbus communication with your building management system (BMS): optional on all units.