QUANTOR COMPUTE by WTG-Quantor Talk to a cooling specialist
Applications

Built for compute wherever compute happens.

From a single test bench to a room of high-density racks, Quantor chillers add liquid cooling where the heat is, without a facility build-out.

Featured installations

Trusted by two leading AI developers.

Two of the world's leading AI developers use Quantor chillers, including a Fortune 500 technology company that has cooled its AI development hardware with them since 2019. It is our most demanding application, and the best proof of what these units can do.

  • A Fortune 500 technology company, in continuous service since 2019
  • A leading AI research company, since 2026
  • Chilly 45, Chilly Max and MCK units in service
Engineering test bench with liquid-cooled servers
Typical fit Chilly 45 · Chilly Max ~4 – 13 kW per bench or cluster
01 · R&D & test labs

Cooling that keeps up with the test schedule.

The challenge

Development labs run prototype accelerators, GPU servers and electronics under changing loads, often in rooms never designed for liquid cooling. Facilities upgrades take months; test schedules don't wait.

How Quantor helps
  • Self-contained units roll in and connect to the test loop the same day
  • Stable supply temperature through test and validation cycles, with the unit sized to your peak load
  • Stainless steel fluid circuit
Size a system for this application →
02 · University & research

Dedicated cooling without touching the central plant.

The challenge

Research groups add compute and instruments faster than campus infrastructure can follow. Tying into the building's chilled water is slow, costly and often not possible.

How Quantor helps
  • A dedicated chiller for the lab, independent of the building's chilled-water plant
  • Air-cooled, so no cooling tower or new piping to the roof
  • Compact footprint for shared or older lab space
Size a system for this application →
University research lab with a server rack
Typical fit Chilly Max · MCK ~6 – 80 kW per lab
Compact edge compute room
Typical fit Chilly Max · MCK ~6 – 80 kW per site
03 · Edge compute

Real cooling where space and power are tight.

The challenge

Edge sites put compute close to where data is created: factories, telecom shelters, retail back rooms, remote facilities. There is rarely spare floor space, power or on-site staff.

How Quantor helps
  • Compact units fit small rooms and utility spaces
  • Single- and three-phase power options for the power you have
  • Simple controls and robust components for sites without daily attention
Size a system for this application →
04 · Server & HPC racks

Add capacity rack by rack.

The challenge

A few high-density servers or HPC nodes can outgrow a room's air cooling overnight. Upgrading the whole room is rarely justified for a handful of racks.

How Quantor helps
  • Cool the racks that need it, not the entire building
  • Scale by adding units as racks are added
  • Top-discharge airflow on Chilly Max and MCK keeps hot exhaust out of the aisle
Using direct-to-chip cooling?

Cold-plate servers usually connect to a chiller through a CDU or heat exchanger. Bring your server or CDU maker's requirements for coolant, flow rate, pressure drop and supply temperature, and we'll match a unit to them.

Size a system for this application →
Liquid-cooled server racks
Typical fit MCK · Chilly Max ~15 – 80 kW per rack group
Robotic production cell
Typical fit Chilly 45 · Chilly Max ~4 – 13 kW per cell
05 · Robotics & automation

Localized cooling at the production cell.

The challenge

Automated production cells increasingly carry their own compute, drives and vision systems. Heat builds up right where the work happens.

How Quantor helps
  • Compact units sit next to the cell they cool
  • Heavy-duty, industrial-grade construction for production floors
  • Stainless fluid circuits for long, uninterrupted duty
Size a system for this application →
06 · Life science & imaging

Steady temperatures for compute-intensive analysis.

The challenge

Imaging and sequencing labs pair sensitive instruments with heavy data processing. Temperature swings can interrupt runs or shorten hardware life.

How Quantor helps
  • Precise, stable supply temperature from German-engineered, high-end units
  • Self-contained, air-cooled units with no tie-in to the building's chilled-water plant
  • Stainless steel fluid circuit
Size a system for this application →
Imaging and analysis lab
Typical fit Chilly Max · MCK ~6 – 80 kW per lab

Don't see your application?

If it runs hot and fits on a liquid loop, we can probably cool it. Tell us about your heat load and we'll find the right unit.

Size my system →